FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-448A · Low Temperature (Freezer)

5 HP walk-in freezer refrigeration system

4 current R-448A condensing units at 5 HP, rated 16,070 BTU/h at 95°F ambient, with the 8 unit coolers matched to that capacity. Sized for a walk-in freezer holding 0°F to -10°F.

Outdoor remote refrigeration condensing unit of the type supplied with a 5 HP walk-in freezer system
5
Horsepower
16,070
BTU/h at 95°F ambient
4
Condensing units
8
Matched evaporators
4 models

5 HP R-448A condensing units

R-448A is the current refrigerant for this class. R-448A is a non-flammable A1 blend and the direct replacement for R-404A.

5 HP R-448A Low Temperature (Freezer) condensing units — 4 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBO500L4SDB Preassembled Remote Indoor / Outdoor Scroll 16,700 16,070 208-230 · 1-ph 33 × 43.875 × 35″ 367 lb
WBO500L4SEB Preassembled Remote Indoor / Outdoor Scroll 16,700 16,070 208-230 · 3-ph 33 × 43.875 × 35″ 367 lb
WFO500L4SDB Preassembled Remote Outdoor Scroll 16,700 16,070 208-230 · 1-ph 33 × 43.875 × 35″ 367 lb
WFO500L4SEB Preassembled Remote Outdoor Scroll 16,700 16,070 208-230 · 3-ph 33 × 43.875 × 35″ 367 lb

Ratings are the manufacturer’s published capacities at -20°F suction for the ambient shown. A dash means the figure is not published for that model — call 954-237-6753 and we will confirm it.

8 unit coolers

Evaporators used with this system

These are the R-448A low-temperature unit coolers used with a 5 HP condensing unit. The evaporator is what decides the room: a low-temperature coil makes it a freezer, a medium-temperature coil makes it a cooler.

R-448A Low Temperature (Freezer) unit coolers matched to 5 HP — 8 models
ModelSeries BTU/hCFMFans DefrostVoltage L × W × H
WE6E125DDS Center Mount Ultra Low Profile Unit Cooler 14,300 1,716 3 Electric 208-230 72 × 28.375 × 11.25″
WE6E137DDS Center Mount Ultra Low Profile Unit Cooler 15,400 2,408 4 Electric 208-230 92 × 28.375 × 11.25″
WE6E182DDS Center Mount Ultra Low Profile Unit Cooler 20,900 2,288 4 Electric 208-230 92 × 28.375 × 11.25″
WL6E121DDAS Low Profile Walk-In Unit Cooler 14,200 2,355 3 Electric 208-230 60.125 × 15.5 × 18.125″
WL6E142DDAS Low Profile Walk-In Unit Cooler 16,600 2,325 3 Electric 208-230 60.125 × 15.5 × 18.125″
WL6E162DDAS Low Profile Walk-In Unit Cooler 18,700 3,140 4 Electric 208-230 76.625 × 15.5 × 18.125″
WL6E182DDAS Low Profile Walk-In Unit Cooler 21,000 3,100 4 Electric 208-230 76.625 × 15.5 × 18.125″
ASLE65150DDS Slim-Temp Reach-In Display Case Unit Cooler 16,200 2,850 6 Electric 208-230 139 × 19.8125 × 9.1875″

Grouped by published capacity against this horsepower class. Note that the two ratings are published at different conditions — the condensing unit at the ambient and suction temperature shown above, the unit cooler at its rated temperature difference — so the BTU figures are not meant to be read against each other one for one. On low-temperature systems the coil is deliberately sized for a small temperature difference, so its rating normally reads higher than the condensing unit’s. The final evaporator for your job depends on the box size, the door traffic, the product going in and the ambient around it — we do that calculation for you before anything is quoted. Call 954-237-6753.

Need this system sized for your box?

Send us the inside dimensions and what you are storing. You get a drawing and a price, not a runaround.

Get a free quote All refrigeration systems

Condensing units are UL and cUL listed for indoor or outdoor use. Unit coolers are UL and cUL listed, NSF approved for use in food preparation areas, and AWEF certified for walk-in coolers and freezers in boxes under 3,000 sq. ft.

← 5 HP R-448A cooler  ·  6 HP R-448A cooler →

Call Now Get a Free Quote